Answers are grounded in this paper and cite their sources.
It will first of all be necessary to define what is meant by intensity. The term is loosely used and not infrequently indicates the dosage per day. In this paper it will be taken to mean the number of r units per minute. Considerable controversy has arisen regarding the relative merits of high and low intensity in the treatment of malignant disease. The problem is of economic and scientific interest. The economic factor alone would justify investigation. Consider a patient to whom it is desired to give a dose of 180 r per day to each of six fields. With a low intensity beam of 3 r per minute the treatment time will be six hours. On the other hand, an intensity of 150 r per minute will reduce this period to seven minutes. That is to say, the treatment time will be fifty times longer and many more tubes will be required in order to treat the same number of patients. Quite apart from the increased cost of additional tubes and generating apparatus there will be far greater expenditure in the erection of a suitable building and in the number of staff required. Furthermore, since the output of an X-ray tube increases with approximately the square of the voltage it follows that a practical embargo is placed on high voltage X-ray work, for these tubes are more expensive and it would be very uneconomical to run them well below their maximum rating.
No takes yet. Share an insight, caveat, or question.
R. W. P. McWhirter (1936) studied this question.