—In this article, a method based on the application of the discrete wavelet transform to the instantaneous reactive power signal, for diagnosing the occurrence of broken rotor bars in induction motors operating under time-varying load conditions, is presented. This method is based on the decomposition of the instantaneous reactive power signal, from which wavelet approximation and detail coefficients are extracted. The energy evaluation of known bandwidths permits to define a fault severity factor. This method has been tested through the simulation of an induction motor using a mathematical model based on the winding-function approach. These simulation results are complemented by experimental tests conducted on an induction motor with several faulty rotors that can be interchanged and both simulation and experimental results have shown the effectiveness of the proposed method for broken rotor bars diagnosis in induction motors even under time-varying load conditions.
No takes yet. Share an insight, caveat, or question.
Yahia et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: