Key result
A quality improvement initiative involving education and standardization improved the median proportion of reported echocardiogram elements from 65% to 71% (p=0.02).
Why the study?
In patients with repaired tetralogy of Fallot, poor adherence to key echocardiogram report elements has been demonstrated, particularly for quantitative assessment of right ventricular function.
Do quality improvement interventions improve adherence to echocardiogram reporting guidelines in patients with repaired tetralogy of Fallot?
Do quality improvement interventions improve adherence to echocardiogram reporting guidelines in patients with repaired tetralogy of Fallot?
Absolute Event Rate: 71% vs 65%
p-value: p=0.02
Standardization and iterative quality improvement interventions can modestly improve adherence to echocardiogram reporting guidelines in congenital heart disease.
QI modestly boosts TOF echo reporting adherence via education and standardization; leaves open whether iterative efforts sustain quantitative RV assessment.
BACKGROUND: In patients with repaired tetralogy of Fallot (TOF), key echocardiogram report elements have been identified, but poor adherence has been demonstrated, particularly for quantitative assessment. We report a quality improvement effort to improve adherence at our institution, with a focus on increasing quantitative assessment of right ventricular (RV) function. METHODS: Baseline compliance was established by a 3-month retrospective review of outpatient echocardiogram reports. Intervention 1 included presenting baseline data and reviewing the guidelines with echocardiogram laboratory staff (physicians and sonographers). Intervention 2, chosen to focus on quantitative assessment of RV function, involved recommending measurement of tricuspid annular plane systolic excursion (TAPSE) for all echocardiograms. Reporting rates were prospectively analyzed for 1 month after each intervention. To evaluate sonographer versus physician compliance, both study images (acquisition of TAPSE images) and reports were reviewed. RESULTS: At baseline, adherence was poor (median 65% of elements reported), with lower rates for measurements versus descriptive elements (median 40% vs 78%, p<.0001). Following intervention 1, total reported elements improved (median 71% vs 65%, p=0.02) due to increase in measurements (median 50% vs 40%, p=0.02). Reports of quantitative RV function did not significantly change after either intervention, but sonographer compliance improved after intervention 1 (33% vs 14%, p=0.03), with further improvement after intervention 2 (53% vs 14%, p=0.001). CONCLUSION: While education on lesion-specific guidelines may modestly improve adherence, standardization has a greater effect. However, interventions may have differential impact on sonographers versus attendings, and iterative interventions may be required to change practice patterns.
No takes yet. Share an insight, caveat, or question.
Srnka et al. (2021) studied Repaired tetralogy of Fallot (TOF). Quality improvement initiative (education and standardization) vs. Baseline (pre-intervention) was evaluated on Total reported echocardiogram elements (p=0.02). A quality improvement initiative involving education and standardization improved the median proportion of reported echocardiogram elements from 65% to 71% (p=0.02).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: