Answers are grounded in this paper and cite their sources.
This article presents a comprehensive investigation of the high-frequency magnetic flux distributions in manganese-zinc ferrite ring cores. New experimental characteristics are presented and used in the flux modeling. The flux distribution is predicted by a one-dimensional analytical model, a transmission-line model, and finite-element analysis. The models are used to investigate the high-frequency effects, such as skin depth and dimensional resonance. A complete experimental validation is presented. The nonuniform magnetic flux distributions are experimentally validated for two Mn-Zn materials: 3F36 and 3E10. The low permeability 3F36 material performance can be significantly degraded by dimensional resonance. However, the high permeability 3E10 material degrades due to the skin effect. The presented analytical methods show a very good correlation with the measurements.
No takes yet. Share an insight, caveat, or question.
Kącki et al. (2022) studied this question.