Transformer designs that achieve efficiencies greater than 99% operating at 2 MHz at power densities in excess of 400 W/in/sup 3/ for the power range of 50-100 W with output voltages of 1.5 V are discussed. To achieve these results, copper density must be increased beyond what is possible with more conventional Litz wire constructions. Instead, multilayer windings are made of copper foil using flex circuit technology. The elimination of external connections between the winding layers by incorporating the interconnections as an integral part of the winding design is described. This results in Z-folded winding structures that can be ultimately interleaved to achieve high copper density, low copper loss, and very low leakage inductance.>