Noise measurement in power line communication (PLC) systems is a common activity performed by grid operators for network tuning operations. Usually, these measurements are carried out with portable devices that have a fixed sensing and storage capacity. In this context, this paper presents a software-only solution for enhancing the performance of noise measurements in PLC systems. In detail: (i) we extend the measurement capacity in terms of the maximum number of samples that can be detected continuously, by using a machine learning (ML)-powered low complexity algorithm; and, (ii) we reduce the discontinuity period between successive measurements. This latter feature enables the possibility of collecting more continuous data. To show the viability of our proposal, we conducted a field measurements campaign to measure the scheme’s accuracy and the measurement capacity extension ratio (MCER). The introduced approach is able to increase the MCER by up to 8 times, in the considered PLC environments, with an accuracy above 90%. While the proposed approach has a clear application—improving current devices’ noise measurements capability without requiring costly hardware upgrades—, the technique herein shown has a general applicability, and could hence pave the way for further applications in related fields.