This paper examines the relationship between rotor design, saliency-based signal injection sensorless control, and power conversion properties for four industrially relevant interior permanent-magnet machine configurations: a 36-slot 6-pole stator with v bar rotor, a 36-slot 6-pole stator with flat bar rotor, a 9-slot 6-pole stator with v bar rotor, and a 9-slot 6-pole stator with flat bar rotor. The influence of rotor geometric design variables over the range of current densities at the maximum torque per ampere angle was found using a design of experiments' methodology and standardized regression coefficients. Tradeoffs between sensorless control and power conversion properties are found using a Monte Carlo methodology. Power conversion and sensorless control properties were analyzed using hybrid static and time-stepping finite-element simulations.