Key result
Echocardiographic cardiac dimensions do not differ significantly across horse disciplines.
Why the study?
Normative echocardiographic heart dimension values and optimal transducer positions for warmblood horses without heart disease were needed to support clinical cardiology.
Cross-Sectional (n=66)
No
B-mode echocardiography is utilized to measure baseline heart dimensions in healthy warmblood horses.
Answers are grounded in this paper and cite their sources.
Supports common B-mode reference ranges across warmblood disciplines; extends equine norms but leaves broader validation open.
Die Hezdimensonen von 46 hezgesunden Warmblutpferden, die irn Rertsport (Dressur und Springen Klasse S) und in der Freizeitreiterei eingesetzt waren, wurden mit Hilfe der Schnittbildtechnik im B-mode ausgemessen.Die Hezen der Pferde wurden in sieben Anschallrichtungen, von dem rechten und linken echokardiographischen Fenster aus in der langen und kuzen Herzachse dargestellt.Neben den Inn€ndurchmessern der Vorhöfe, Ventrikel, Hezostien und der Aorta und Pulmonalarterie wurde das lvlyokard im Bereich der rechten und linken Herz'/vand sowio des interventrkulären Septums vermessen.Außerdem wurde die Fläche des Schnittbildes der Aortenklappenebene und die linksventrikuläre Verkür zungsfraktion bestimmt.Bei dem Vergleich von Sprng-und Dressurpferden einerseits und Sportpferden und Freizeitpferden andererseits wurden keine signifikanten Unterschiede der Hezdimensionen festgestellt.Aufgrund der kardiologischen Diagnostik der letzten Jahre ergab sich zusätzlich die Notvvendigkeit den Durchmesser der Aorta im Bereich des sinus valsalvae bei gesunden Pferden zu bestimmen.Deshalb wurde dieser Parameter bei weiteren 20 hetzgesunden Warmblutpferden zu einem späteren Zeitpunkt untersucht und in die vorliegende Mitteilung einbezogen, Für die echokardiographische Routineuntercuchung werden bestimmte Anlotungspositionen vorgoschlagen.Weitere Anlotungspositionen werden nur für spezielle weitergehende Fragestellungen notwendig.Dje hier erarbejteten Normwerte bilden eine praktikable Grundlage für die Beurteilung von Herzdimensionen beim Warmblutpferd.Sie haben sich in den letzten Jahren bei 450 echokardiographisch untersuchten Hezpatienten bewährt, Schlüsselwörter: B-mode Echokardiographie, Warmblutpferd, Herzdimensionen, Normalwerte, Schallkopfpositionen B-mode echocardiographic measurement of heart dimensions in warm bloodad ho6es without heart disease Heart dimensions of 46 warmblooded horses (Dressage-, Show jumping horses and Pleasure horses) without heart disease were measured by real-time echocardiography in B-mode.Hearts were monrtored in seven transducer positions from right and left echocardiographic window.Internal diameters of atrals, ventricles, valves, aorta and pulmonary artery as well as rnyocardial dimensions of right and left ventricle wall and interventricular septum were determ ned.Additionally plane of aortic valve area and shortening fraction (FS%) of left ventricle were measured.Comparison between jumping and dressage horses on one hand and between these competition horses and pleasure horses on the other hand did not show significant differences of heart djmensions.Clinical and echocardiographical cardiology of the recent years revealed the diameter of aorta in the region of sinus valsalvae as a helpful parameter to answer several questions.On this account this parameter were evaluatsd subs€quent in 20 additionally examined heart healthy warm blooded horses.Special transducer positions for routine echocardiographic diagnosis in the horse are proposed.Beyond that further transducer positions for selected diagnostic questions are available.The presented standards were useful in evaluation of heart dimension in 450 warm blooded horses with heart disease, which were examined echocardiographically.
No takes yet. Share an insight, caveat, or question.
Štádler et al. (1996) conducted a cross-sectional in Healthy (no heart disease) (n=66). Equestrian discipline (Dressage, Show jumping, Pleasure) vs. Between-group comparison was evaluated on Differences in B-mode echocardiographic heart dimensions between activity groups (p=>0.05). B-mode echocardiographic measurements revealed no significant differences in cardiac dimensions among healthy warm-blooded dressage, show jumping, and pleasure horses.
Synapse has enriched 10 related papers. Consider them for comparative context: