Key result
A custom 3D fully convolutional neural network improved ultrasound image contrast, GCNR, and LOC compared to short-lag spatial coherence imaging and spatial prediction filtering.
Why the study?
Diffuse reverberation causes spatially incoherent ultrasound image noise that degrades image quality, adaptive beamforming, and velocity or displacement estimation.
Does a 3D fully convolutional neural network improve image quality metrics compared to SLSC and FXPF in ultrasound imaging?
Does a 3D fully convolutional neural network improve image quality metrics compared to SLSC and FXPF in ultrasound imaging?
A novel 3D fully convolutional neural network effectively suppresses diffuse reverberation noise in ultrasound channel signals, improving image quality metrics over existing methods.
May enhance channel-signal processing for elastography and Doppler; leaves open prospective clinical validation before adoption.
Diffuse reverberation is ultrasound image noise caused by multiple reflections of the transmitted pulse before returning to the transducer, which degrades image quality and impedes the estimation of displacement or flow in techniques such as elastography and Doppler imaging. Diffuse reverberation appears as spatially incoherent noise in the channel signals, where it also degrades the performance of adaptive beamforming methods, sound speed estimation, and methods that require measurements from channel signals. In this paper, we propose a custom 3D fully convolutional neural network (3DCNN) to reduce diffuse reverberation noise in the channel signals. The 3DCNN was trained with channel signals from simulations of random targets that include models of reverberation and thermal noise. It was then evaluated both on phantom and in-vivo experimental data. The 3DCNN showed improvements in image quality metrics such as generalized contrast to noise ratio (GCNR), lag one coherence (LOC) contrast-to-noise ratio (CNR) and contrast for anechoic regions in both phantom and in-vivo experiments. Visually, the contrast of anechoic regions was greatly improved. The CNR was improved in some cases, however the 3DCNN appears to strongly remove uncorrelated and low amplitude signal. In images of in-vivo carotid artery and thyroid, the 3DCNN was compared to short-lag spatial coherence (SLSC) imaging and spatial prediction filtering (FXPF) and demonstrated improved contrast, GCNR, and LOC, while FXPF only improved contrast and SLSC only improved CNR.
No takes yet. Share an insight, caveat, or question.
Brickson et al. (2021) studied Ultrasound image noise. 3D fully convolutional neural network (3DCNN) vs. Short-lag spatial coherence (SLSC) imaging and spatial prediction filtering (FXPF) was evaluated on Image quality metrics (GCNR, LOC, CNR, and contrast). A custom 3D fully convolutional neural network improved ultrasound image contrast, GCNR, and LOC compared to short-lag spatial coherence imaging and spatial prediction filtering.