Why the study?
Does 50% inspired oxygen compared to 25% inspired oxygen improve pulmonary oxygenation in ASA Grade I patients undergoing elective abdominal surgery?
Does 50% inspired oxygen compared to 25% inspired oxygen improve pulmonary oxygenation in ASA Grade I patients undergoing elective abdominal surgery?
Intra-operative mechanical ventilation with 50% inspired oxygen does not significantly affect pulmonary gas exchange compared to 25% inspired oxygen in healthy patients undergoing elective abdominal surgery.
Answers are grounded in this paper and cite their sources.
50% inspired oxygen confers no gas exchange benefit over 25% in healthy abdominal surgery patients; confirms lower FiO2 suffices without compromising oxygenation.
Forty-three ASA Grade I patients scheduled for elective abdominal surgery received at random either 25% or 50% inspired oxygen for intra-operative mechanical ventilation lasting 4-6 h. Pulse oximetry was monitored continuously. Venous admixture was assessed from the PaO2/FIO2 ratio and was measured twice intraoperatively: at the time of incision, and during surgical wound closure. PaO2 was measured 1 h after extubation having breathed room air for 10 min, if tolerated. The patients in the two groups were similar in regard to general characteristics, and had similar operations. Patients given oxygen 50% had operations that lasted longer, which made the trial more sensitive. The inspired oxygen did not affect pulmonary gas exchange either within each group or between groups under the conditions of the study. In no patient did pulse oximetry record an oxygen saturation below 95% intra-operatively.
No takes yet. Share an insight, caveat, or question.
Lentschener et al. (1997) studied this question.