Answers are grounded in this paper and cite their sources.
In Brief Objective: The range of pitch sensations available in cochlear implants (CIs) is conventionally thought to be limited by the location of the most apical and basal electrodes. However, partial bipolar stimulation, in which current is distributed to two intracochlear electrodes and one extracochlear electrode, can produce “phantom electrode” (PE) pitch percepts that extend beyond the pitch range available with physical electrodes. The goals of this study were (1) to determine the PE configuration that generated the lowest pitch relative to monopolar (MP) stimulation of the most apical electrode and (2) to determine the amount of pitch shift produced by different PE configurations. Design: Ten Advanced Bionics CI users (9 unilateral and 1 bilateral), implanted with the CII or HiRes 90k implant and the HiFocus 1, HiFocus 1j, or Helix electrode arrays participated in this study. PEs were created by simultaneously stimulating the primary and compensating electrodes in opposite phase. To test different PE configurations, the proportion of current delivered to the compensating electrode (σ) and the electrode separation between the primary and compensatory electrode (D) were varied. To estimate the relative pitch of PEs, the lowest pitched PEs with primary electrodes 4 and 8 were compared with subsets of MP electrodes (1, 2, 3, 4, 5 and 5, 6, 7, 8, 9, respectively). Results: In all subjects, it was possible to identify σ and D values that produced a PE that was lower in pitch than the MP stimulation of the primary electrode. In some subjects, increasing σ and/or D produced progressively lower pitch percepts, whereas in others, PE pitch changed nonmonotonically with σ and/or D. The amount of PE pitch shift could be estimated only for 14 cases; in seven cases, the pitch shift was <1 MP electrode, and in seven other cases, the pitch shift was between 1 and 2 MP electrodes. Conclusions: PE stimulation can elicit pitch percepts lower than that of the most apical MP electrode; the PE pitch is lower by the equivalent of 0.5 to 2 MP electrodes. The results obtained in this study suggest that phantom electrode stimulation can be used to extend the range of pitch sensations produced by electrical stimulation of the cochlea through a cochlear implant. The amount of current compensation and electrode separation which generated the lowest pitch sensation varied across different cochlear implant users. In half of the conditions phantom electrode technique generated a pitch sensation that was lower than that associated with monopolar stimulation of the primary electrode by more than 1 electrode.
No takes yet. Share an insight, caveat, or question.
Saoji et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: