Answers are grounded in this paper and cite their sources.
Objective: To investigate the outcomes of internal limiting membrane (ILM) peeling using microperimetry (MP) and multifocal electroretinogram (mfERG) instruments. Material and Methods: Forty-two eyes of 42 patients with ILM peeling were evaluated. Unity of outer stratums was assessed using spectral-domain optic coherence tomography. MfERG parameters (N1 and P1 amplitude, implicit time) and MP parameters were also measured both at baseline and month-12. Results: The mean P1 amplitude in ring 1 increased according to the baseline value (p = 0.002). However, the mean P1 amplitudes were lower compared with baseline values in mfERG in rings 2, 3, 4, and 5 (p = 0.016 for ring 2 and p < 0.001 for other rings). According to the preoperative retinal sensitivity of each of 37-point in MP, there was a reduction of 22.1% at month-12 in the ILM peeling area, and absolute microscotomas were detected in two points of two eyes at month-12. Metamorphopsia was associated with disrupted ellipsoid zone at month-12 (OR = 6.75, p = 0.008). Conclusion: The potential risk of a decrease in postoperative macular sensitivity should be taken into consideration if ILM peeling is planned in macular hole surgery.
No takes yet. Share an insight, caveat, or question.
Sami Yılmaz (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: