This review highlights that pre-existing conduction disorders and the use of the CoreValve prosthesis are major predictors for permanent pacemaker implantation following TAVI, emphasizing the need for careful screening and monitoring.
Answers are grounded in this paper and cite their sources.
May inform pre-TAVI conduction screening and prosthesis choice; leaves open prospective validation in contemporary cohorts.
The presence of periprocedural conduction disorders (CDs) and the need for permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) are frequent findings in clinical practice. Notwithstanding, robust information on the prognostic and therapeutic implications of these complications are lacking. The newly occurrence of CD after TAVI seems related to the trauma of the conduction system during procedure. On the contrary, major predictors for PPM implantation after TAVI seem to be the use of CoreValve prosthesis (Medtronic, Minneapolis, MN) and the presence of CD before TAVI. An accurate pre-TAVI screening, careful valve implantation, as well as post-TAVI monitoring must be pursued to prevent avoidable PPM implantation. The aim of this report is to analyze the available data on this field and to propose some practical clinical tips to prevent or to manage these complications.
No takes yet. Share an insight, caveat, or question.
Fraccaro et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: