Answers are grounded in this paper and cite their sources.
Temperatures of mice were measured using an infrared high performance non-contact thermometer, after the device had been calibrated using implantable microchips containing temperature transponders. Mice were infected with three species of Candida (isolates) and the resultant disseminated infections monitored. Mouse temperatures could be reliably measured using the infrared device and this measurement caused little distress to the mice. We were further able to demonstrate that mice rarely recovered if their body temperature dropped below 33.3 degrees C (sensitivity 68%, specificity 97%). Adoption of a 33.3 degrees C endpoint in fungal sepsis experiments measured by infrared non-contact thermometer would significantly reduce the suffering in the terminal stages of this type of infection model.
No takes yet. Share an insight, caveat, or question.
Warn et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: