Answers are grounded in this paper and cite their sources.
Herein, we report a significant improvement in the medium- to long-term frequency stability of our pulsed optically pumped (POP) vapor-cell rubidium clock. Such an achievement is established with the better control of our system and the environment. An integrated optical module, including a distributed Bragg reflector laser and an acousto-optic modulator, is developed to improve the stability of the laser. The physics package is sealed in a vacuum chamber with a vacuum of 4 × 10−4 Pa to significantly reduce the impacts of the barometric effect. An AC-driven heater is placed much closer to the cell to enable a better temperature control. The resolution of the servo control voltage is also optimized. With all these improvements, a frequency stability of 4.7 × 10−15 at 104 s in terms of the Allan deviation is obtained. We also estimate the main noise sources that limit the frequency stability of the POP atomic clock.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: