Retrospective study demonstrates superior fetal anomaly detection with an expanded 30-plane first-trimester ultrasound protocol, indicating enhanced early diagnostic performance.
OBJECTIVE: To evaluate the clinical utility of a novel comprehensive StaFFAUS (standardized first-trimester fetal anatomic ultrasound screening) protocol. METHODS: This retrospective single-center study included pregnant patients undergoing first-trimester ultrasound screening at 11 6/7–13 6/7 weeks of gestation between 2013 and 2024. Identification of gold-standard–confirmed anomalies was assessed retrospectively according to an expanded first-trimester screening protocol with 30 imaging planes called StaFFAUS, the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) Minimum-Requirement, and the ISUOG Detailed protocols. Diagnostic performance was evaluated in a subset validation cohort made up of all fetuses with structural abnormalities and a control group without structural abnormalities, selected at a 1:3 ratio. Examination time was assessed in 100 randomly selected scans. Pairwise DeLong comparisons were used to compare the area under the receiver operating characteristic curve (AUROC) between groups. RESULTS: A total of 18,250 women carrying 19,417 fetuses were considered for inclusion. First-trimester screening identified 246 fetuses with structural abnormalities, comprising 580 individual detected anomalies (3.0%). Using 694 gold-standard–confirmed anomalies as the reference standard, StaFFAUS achieved a significantly higher anomaly-level detection rate than the ISUOG Detailed protocol (83.6% vs 67.3%, P <.001) and the ISUOG Minimum-Requirement protocol (83.6% vs 47.7%, P <.001). In the diagnostic performance cohort of 326 fetuses with anomalies and 978 fetuses in a matched control group (N=1,304), StaFFAUS showed the highest sensitivity (75.5%), accuracy (90.8%), and AUROC (0.857, 95% CI, 0.830–0.884), whereas the ISUOG Minimum-Requirement protocol achieved the highest specificity (99.0%). The AUROC of StaFFAUS was significantly higher than those of both the ISUOG Detailed (AUROC 0.820, P <.001) and ISUOG Minimum-Requirement (AUROC 0.769, P <.001) protocols. Median examination time was 28 minutes (interquartile range 22–35.5 minutes). CONCLUSION: Compared with current ISUOG first-trimester screening protocols, StaFFAUS demonstrated superior anomaly detection and diagnostic performance. As an expanded standardized screening framework incorporating additional first-trimester anatomic views, it improves early detection of fetal structural abnormalities while remaining clinically feasible.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: