Experimental study demonstrates systematic decrease of fracture toughness with pre-strain in SUS316L stainless steel at cryogenic temperatures, indicating risks for cryogenic hydrogen storage.
Large hydrogen storage tanks are often fabricated from metastable austenitic stainless steels, yet residual fracture resistance after pre-straining under cryogenic service conditions is not fully quantified. This difficulty reflects coupled effects of cryogenic temperature, hydrogen environment, and strain-induced martensitic transformation. We introduced pre-strain at ten uniaxial tensile levels and performed 18 compact-tension tests for SUS316L under two cryogenic conditions. Eight conditions were tested at 20 K in liquefied hydrogen, and ten conditions were tested at 77 K in liquefied nitrogen. Fracture toughness decreased systematically with increasing pre-strain at both temperatures. Among the 18 tests, 12 showed significant pop-ins. These were treated according to ASTM E1820 by adopting 𝐽 Q u at the earliest significant event and excluding data acquired after that event from 𝐽 R regression. For trend representation, we employed a modified three-parameter Cosham-type model within an HRR-based framework and calibrated early-stage resistance using 𝐽 Q . The model reproduced the observed pre-strain dependence and provides a quantitative basis for screening and fitness-for-service assessment after severe events in large cryogenic hydrogen storage tanks.
No takes yet. Share an insight, caveat, or question.
Morohoshi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: