Key result
Contrast-enhanced ultrasonography was superior to color Doppler ultrasound in identifying Shamblin type I or III carotid body tumors and visualizing feeding vessel origins, though it was less sensitive in detecting feeding vessels overall (88% vs 100%, p=0.010).
Why the study?
The study was conducted to prospectively explore the characteristics and enhancement patterns of carotid body tumors and compare color Doppler ultrasound with contrast-enhanced ultrasonography for evaluating tumor morphology and vascularity.
Does contrast-enhanced ultrasonography improve the evaluation of morphology and vascularity in carotid body tumors compared to color Doppler ultrasound?
Observational (n=20)
Single-blind
No
Does contrast-enhanced ultrasonography improve the evaluation of morphology and vascularity in carotid body tumors compared to color Doppler ultrasound?
Contrast-enhanced ultrasonography provides superior evaluation of Shamblin type, vascularity, and feeding vessel origins for carotid body tumors compared to conventional color Doppler ultrasound, aiding in preoperative planning.
May aid preoperative carotid body tumor assessment; leaves open need for prospective validation before practice change.
Objective The objectives of this study were to prospectively 1) explore the characteristics and enhanced patterns of carotid body tumors (CBTs) at color Doppler ultrasound (CDU) and contrast-enhanced ultrasonography (CEUS) qualitatively and quantitatively and 2) compare CDU and CEUS for their morphology and vascularity signature. Methods CDU and CEUS with Sonovue® were used to evaluate 25 CBT lesions. The comparison between these ultrasonic modalities included the size, Shamblin type, vascularity, and feeding vessels of the lesion areas. The time–intensity curve (TIC) analysis was used to obtain the dynamics of the contrast-enhancement features of CBTs. Results The TIC analysis presented a fast wash-in [wash-in time: 3.00 ± 1.10 s, mean ± SD] and slow wash-out [wash-out time: 58.79 ± 24.21 s, mean ± SD] pattern in the CBT lesions, with a high area under the curve (AUC) of 669.68 ± 143.46 mm2 (mean ± SD). In comparison with CDU, CEUS was superior in identifying Shamblin type I or III CBT lesions (χ2 = 17.389, p=0.002). It detected a significant difference in the AUC between moderate and marked vascularity groups (563.33 ± 102.63 vs. 707.22 ± 138.81, t=-2.311, p=0.031.), while CDU observed no significant difference between these two groups. Although CDU was more sensitive than CEUS in detecting feeding vessels (100% vs. 88%), CEUS better visualized the origins of feeding vessels (χ2 = 9.162, p=0.010). Conclusion CEUS can better investigate the Shamblin type and vascularity of CBT lesions than CDU. CBTs displayed a fast wash-in, slow wash-out pattern with high AUC in the TIC analysis in the CEUS mode. CDU is more sensitive in detecting feeding vessels than CEUS, while CEUS can better visualize the origins of feeding vessels.
No takes yet. Share an insight, caveat, or question.
Gu et al. (2022) conducted an observational in Carotid Body Tumors (n=20). Contrast-enhanced ultrasonography vs. Color Doppler ultrasound was evaluated on Detection of feeding vessels (p=0.010). Contrast-enhanced ultrasonography was superior to color Doppler ultrasound in identifying Shamblin type I or III carotid body tumors and visualizing feeding vessel origins, though it was less sensitive in detecting feeding vessels overall (88% vs 100%, p=0.010).