Key result
Patient-specific ATAA computational modeling reveals an ~18% increase in valvulo-arterial impedance index.
Why the study?
Aortic elongation from heart motion and aortic length are emerging as potential indicators of adverse events in ascending thoracic aortic aneurysms, yet simulating these aneurysms while accounting for cardiac mechanics remains technically challenging.
Answers are grounded in this paper and cite their sources.
Patient-specific computational modeling demonstrates that cardiac motion significantly increases aortic wall tension and longitudinal stress in the major curvature of ascending thoracic aortic aneurysms.
In ascending thoracic aortic aneurysms (ATAAs), aneurysm kinematics are driven by ventricular traction occurring every heartbeat, increasing the stress level of dilated aortic wall. Aortic elongation due to heart motion and aortic length are emerging as potential indicators of adverse events in ATAAs; however, simulation of ATAA that takes into account the cardiac mechanics is technically challenging. The objective of this study was to adapt the realistic Living Heart Human Model (LHHM) to the anatomy and physiology of a patient with ATAA to assess the role of cardiac motion on aortic wall stress distribution. Patient-specific segmentation and material parameter estimation were done using preoperative computed tomography angiography (CTA) and ex vivo biaxial testing of the harvested tissue collected during surgery. The lumped-parameter model of systemic circulation implemented in the LHHM was refined using clinical and echocardiographic data. The results showed that the longitudinal stress was highest in the major curvature of the aneurysm, with specific aortic quadrants having stress levels change from tensile to compressive in a transmural direction. This study revealed the key role of heart motion that stretches the aortic root and increases ATAA wall tension. The ATAA LHHM is a realistic cardiovascular platform where patient-specific information can be easily integrated to assess the aneurysm biomechanics and potentially support the clinical management of patients with ATAAs.
No takes yet. Share an insight, caveat, or question.
Cutugno et al. (2021) studied Ascending thoracic aortic aneurysm (ATAA) (n=1). Patient-specific Ascending Thoracic Aortic Aneurysm (ATAA) Living Heart Human Model (LHHM) vs. Healthy aorta in unmodified Living Heart Human Model (LHHM) was evaluated on Valvulo-arterial impedance index (mmHg/mL/m2). Patient-specific ATAA modeling with the Living Heart Human Model showed an 18% increase in valvulo-arterial impedance index and 8.2 mm downward displacement at peak contraction.
Synapse has enriched 10 related papers. Consider them for comparative context: