Answers are grounded in this paper and cite their sources.
This work presents three fuzzy variable structure control (FVSC) techniques applied to the current control loop in a three-phase synchronous rectifier. These techniques are based in a Takagi-Sugeno (T-S) fuzzy PI controller. The first controller is a first-order FVSC, used as a reference. Then, two FVSC strategies are presented and tested, a second and a third-order FVSC. These control schemes are first simulated and then tested in a general-purpose laboratory synchronous rectifier test bench. Experimental results show that control performance is good in all three schemes, achieving current harmonic compensation and power factor correction.
No takes yet. Share an insight, caveat, or question.
Berzoy et al. (2015) studied this question.