Answers are grounded in this paper and cite their sources.
The windup phenomenon occurs and results in performance degradation while the designed positioning controller output makes actuators saturated. This study presents significant and effective anti-windup controllers for performance improvement and comparison of the position tracking. To address real-world industrial scenarios, the trajectory with a T-curve velocity profile is planned to regulate hardware limitations and maintain efficiency throughout the control process. At first, the dynamic model of an inertia load for a servo control system is established using Newton’s law of motion. Then, anti-windup controllers are designed and implemented based on basic PID controllers. The conducted simulations validate its effectiveness and feasibility. Finally, experimental results demonstrate that the proposed algorithms achieve smaller overshoot and faster settling time under input saturations when executing specific paths on the X-Y platform, even though the given control commands change. It is verified that the proposed approaches can, indeed, effectively mitigate the windup phenomenon, leading to improved positioning accuracy in industrial applications.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied this question.