Key result
The Detect-Plus combination test demonstrated 100% sensitivity with only 0.56% presumed false-positives for detecting HIV and HTLV antibodies compared to routine screening assays.
Why the study?
Does the Detect-Plus combination test accurately detect antibodies to HIV-1, HIV-2, HTLV-I, and HTLV-II compared to routine commercial screening assays in STD patients?
Cross-Sectional (n=356)
Does the Detect-Plus combination test accurately detect antibodies to HIV-1, HIV-2, HTLV-I, and HTLV-II compared to routine commercial screening assays in STD patients?
The Detect-Plus combination assay is a highly sensitive and specific screening method for simultaneous detection of antibodies to human retroviruses.
Answers are grounded in this paper and cite their sources.
Supports combined retroviral screening evaluation in STD clinics; leaves open prospective performance and practice impact.
A new generation combination test (Detect-Plus, IAF BioChem, Montreal, Canada) based on synthetic peptides for HIV-1, HIV-2, HTLV-I, and HTLV-II was compared with three routine commercial screening assays and confirmatory assays to determine its sensitivity and specificity and to evaluate it as a substitute screening method. Samples from 356 sexually transmitted disease (STD) patients were tested by the four screening tests. All initially reactive samples were retested in duplicate by the corresponding EIA and repeatedly reactive samples were confirmed by Western blots for HIV-1, HIV-2, and HTLV-I/II. The confirmed positives detected by each screening assay were HIV-1 (23/356, 6.46%), HIV-2 (11/356, 3.09%), and HTLV-I/II (5/356, 1.4%). The new generation Detect-Plus test produced only two results (2/356, 0.56%) that were presumed to be false-positives in comparison to the screening tests, but the OD/CO values were just slightly high (1.5 and 1.9). There were no false-negative results, indicating that the sensitivity of the new combination test was excellent (100%). Compared with routine retroviral EIA assays, the test is easy to perform--the total time requirement is only 2 hr and there is no need for incubation equipment. The OD/CO values were very high when samples were positive, making even visual interpretation possible. We conclude that this new combination assay is an excellent screening method for detection of antibodies to the human retroviruses, and may be particularly useful for screening blood for transfusion and in epidemiological investigations.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (1992) conducted a cross-sectional in Sexually transmitted disease (STD) (n=356). Detect-Plus combination test vs. Routine commercial screening assays was evaluated on Sensitivity and specificity for detection of antibodies to HIV-1, HIV-2, HTLV-I, and HTLV-II. The Detect-Plus combination test demonstrated 100% sensitivity with only 0.56% presumed false-positives for detecting HIV and HTLV antibodies compared to routine screening assays.