Key result
High-power, high-frequency, continuous wave ultrasound reversibly abbreviated the time interval from end diastole to peak (-)dP/dt in canine left ventricles.
Why the study?
Does intracavitary high-power, high-frequency continuous wave ultrasound alter left ventricular performance in an in vivo canine model?
Does intracavitary high-power, high-frequency continuous wave ultrasound alter left ventricular performance in an in vivo canine model?
High-power, high-frequency intracavitary ultrasound reversibly impairs left ventricular performance, likely due to transient alteration of endocardial endothelium function.
Answers are grounded in this paper and cite their sources.
Ultrasound may reversibly impair canine LV performance; leaves open human translation and therapeutic relevance.
Irradiation of isolated cardiac muscle by high-power, high-frequency, continuous wave ultrasound selectively damages endocardial endothelium (EE). We evaluated this ultrasound effect in vivo on the performance of the intact ejecting canine left ventricle (LV). A cylindrical ultrasound probe (0.9 MHz, 25 W), mounted on a catheter, was inserted in the LV cavity through an apical stab wound and was activated for 60, 120, and 240 s, followed each time by a recovery period of 10-15 min. Ultrasound transiently and repeatedly abbreviated the time interval from end diastole to peak (-)dP/dt (from 241 +/- 30 to 229 +/- 32 ms after 240 s; P < 0.001), accelerated LV pressure fall, did not alter peak (+)-dP/dt or peak systolic pressure, increased diastolic and systolic segment lengths, and decreased fractional shortening. Microscopic analysis revealed dispersed granulocytes attached to the EE. EE cells were visibly damaged only in a limited area surrounding the probe. Accordingly, high-power, high-frequency, continuous wave ultrasound reversibly modulated LV performance, presumably by transient alteration of EE function.
No takes yet. Share an insight, caveat, or question.
Gillebert et al. (1992) studied Left ventricular performance. High-power, high-frequency, continuous wave ultrasound vs. Baseline was evaluated on Time interval from end diastole to peak (-)dP/dt (p=< 0.001). High-power, high-frequency, continuous wave ultrasound reversibly abbreviated the time interval from end diastole to peak (-)dP/dt in canine left ventricles.
Synapse has enriched 10 related papers. Consider them for comparative context: