Answers are grounded in this paper and cite their sources.
IgG-coated RBCs are routinely used to confirm appropriate procedures when negative hemagglutination occurrs in the indirect antiglobulin test (IAT). We undertook this study after encountering a case of agglutination failure of IgG-coated RBCs by polyethyleneglycol (PEG)-IAT in a patient with hyperglobulinemia.We investigated whether IgG-coated RBCs could be agglutinated by anti-IgG using the PEG-IAT technique after incubation with 143 sera, in which no irregular anti-red cell antibodies were present, from patients with hyperglobulinemia.Failure of agglutination (false negative reaction) was found more frequently (p<0.001) with the original PEG-IAT (4 drops in test mixture) (46/143 sera; 32%) than the modified PEG-IAT (2 drops) (15/143 sera; 11%). The rate of residual-IgG in the supernatant in the mixture of PEG and patient's serum was significantly (p<0.01) higher with the modified than the original method, at 14.4% vs. 3.0% in hyperglobulinemia patients and 28.5% vs. 5.7% in healthy controls.The addition of anti-D alloantibody (final titer 1:4) in 3, 000-5, 000mg/dL of immunoglobulin concentration revealed that PEG could cause false-negative IAT results due to the neutralization of anti-IgG through precipitation of immunoglobulins in testing tubes.Albumin-IAT, low ionic strength solution-IAT or saline-IAT may assist in resolving interference by PEG in cases of hyperglobulinemia.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: