Answers are grounded in this paper and cite their sources.
Background. Posterior spinal fusion with multisegmental fixation with pedicle screws is the method of choice in the treatment of patients with severe scoliosis. Malposition of pedicle screws, as a cause of implant-associated complications when using the free-hand technique of their implantation, occurs with a frequency of 1.5 to 50.0%. High risks of implant-associated complications require the widespread implementation of technologies for their prevention, including O-arm navigation and additive technologies. Aims — to compare the accuracy and safety of surgical correction of scoliosis using the free-hand technique, O-arm navigation and additive technologies to reduce the risk of implant-associated complications. Methods. A total of 72 patients operated on for scoliotic deformity were included in the study. Group I included 25 patients (447 screws) operated on using the free-hand technique of transpedicular screw implantation, group II included 25 patients (528 screws) operated on using O-arm navigation, and group III included 22 patients (430 screws) operated on using additive technologies based on 3D printing. A comparative analysis of the frequency and distribution of malpositions was carried out in the groups, as well as a search for relationships between various radiographic parameters. Results. In the free-hand group, the average angle of deformation before surgery was 78.48 ± 18.28, the total frequency of malpositions was 16.6%, including: grade 1 — 2.01%, grade 2 — 6.94%, grade 3 — 7.6%. In the O-arm group, the angle of deformation was 90.84 ± 30.16, a total of malpositions was 4.92%, including: grade 1 — 1.52%, grade 2 — 2.84%, grade 3 — 0.57%. In the 3D printing group, the average angle was 95.36 ± 20.93, a total of malpositions was 6.28%, including: grade 1 — 3.72%, grade 2 — 2.33%, grade 3 — 0.23%. When assessing the relationship between the rotation of the apical vertebra and the Cobb angle of deformation on the frequency of malpositions in the free-hand group, a high degree of direct relationship was found (p 0.05). No correlation was found between the frequency of malpositions and rotations of the apical vertebra and the Cobb angle of deformation in the O-arm group. In the 3D group, a moderate correlation was observed (p 0.05). In the free-hand group, 1 neurological complication was noted, in the O-arm and 3D groups, no complications were noted. Conclusions. The use of free-hand — the technique of installing pedicle screws in surgical correction of spinal deformities is relatively safe. However, an increase in the severity of spinal deformity is associated with a high risk of implant-associated complications in severe spinal deformities. The use of O-arm navigation and additive technologies significantly reduces the risk of implant-associated complications, which increases the effectiveness and safety of surgical correction of severe forms of scoliosis.
No takes yet. Share an insight, caveat, or question.
Pimburskiy et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: