A modified indentation technique for measuring toughness is described. The method retains the elastic/plastic basis of previous contact fracture descriptions but eliminates explicit reference to residual stress parameters in the toughness formulation. Accordingly, improved correlations between indentation data and “conventional” K c values are obtained, even for materials (e.g. anomalous glasses) with nonideal deformation responses .
No takes yet. Share an insight, caveat, or question.
Cook et al. (1983) studied this question.