Key result
Holter-derived hourly ectopic variability identifies RVOT ventricular arrhythmia origin with ~90% accuracy, outperforming ECG algorithms.
Why the study?
Predicting the site of origin of outflow tract ventricular arrhythmia before ablation informs patient consent and procedural planning, but whether ectopy variability on ambulatory ECG can accurately predict the site of origin was unknown.
Does hourly variability in outflow tract ectopy on 24-hour ambulatory ECG accurately predict the site of origin in patients with outflow tract ventricular arrhythmia?
Cohort (n=69)
Single-blind
No
Does hourly variability in outflow tract ectopy on 24-hour ambulatory ECG accurately predict the site of origin in patients with outflow tract ventricular arrhythmia?
Ventricular ectopic variability and the presence of a single hour with < 50 VE on 24-hour Holter monitoring can accurately predict the site of origin of outflow tract ventricular arrhythmias, performing favorably compared to existing ECG algorithms.
Answers are grounded in this paper and cite their sources.
May aid noninvasive prediction of RVOT origin in outflow tract ectopy; leaves open prospective validation versus ECG algorithms.
Introduction: Prior to ablation, predicting the site of origin (SOO) of outflow tract ventricular arrhythmia (OTVA), can inform patient consent and facilitate appropriate procedural planning. We set out to determine if OTVA variability can accurately predict SOO. Methods: Consecutive patients with a clear SOO identified at OTVA ablation had their prior 24-hour ambulatory ECGs retrospectively analysed (derivation cohort). Percentage ventricular ectopic (VE) burden, hourly VE values, episodes of trigeminy/bigeminy, and the variability in these parameters were evaluated for their ability to distinguish right from left sided SOO. Effective parameters were then prospectively tested on a validation cohort of consecutive patients undergoing their first OTVA ablation. Results: High VE variability (coefficient of variation ≥ 0.7) and the presence of any hour with < 50 VE, were found to accurately predict RVOT SOO in a derivation cohort of 40 patients. In a validation cohort of 29 patients, the correct SOO was prospectively identified in 23/29 patients (79.3%) using CoV, and 26/29 patients (89.7%) using VE < 50. Including current ECG algorithms, VE < 50 had the highest Youden Index (78), the highest positive predictive value (95.0%) and the highest negative predictive value (77.8%). Conclusion: VE variability and the presence of a single hour where VE < 50 can be used to accurately predict SOO in patients with OTVA. Accuracy of these parameters compares favourably to existing ECG algorithms.
No takes yet. Share an insight, caveat, or question.
Waight et al. (2021) conducted a cohort in Outflow tract ventricular arrhythmia (OTVA) (n=69). 24-hour ambulatory ECG ventricular ectopic (VE) variability parameters (any hour with <50 VEs and coefficient of variation ≥0.7) vs. Established ECG morphological algorithms (transitional zone index [TZI] and V2S/V3R index) was evaluated on Correct prediction of outflow tract ventricular arrhythmia site of origin (RVOT vs LVOT) in the prospective validation cohort using <50 VEs in any hour. Having any hour with <50 ventricular ectopics on 24-hour Holter predicted right ventricular outflow tract origin with 89.7% accuracy, outperforming standard ECG algorithms.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: