Key result
Paravalvular positioning of pacemaker leads had a 2.5% rate of lead revisions compared to 15.4% for conventional transvalvular leads (P=0.286) after tricuspid valve replacement.
Why the study?
Leaving an existing pacemaker lead in an extravalvular position may be an alternative after tricuspid valve replacement, but the short- to mid-term outcomes regarding lead survival and prosthesis dysfunction needed evaluation.
Does alternative pacemaker lead positioning (paravalvular or coronary sinus) reduce lead revisions and prosthesis dysfunction compared to conventional transvalvular leads in patients with tricuspid valve replacement?
Case-Control (n=80)
No
Does alternative pacemaker lead positioning (paravalvular or coronary sinus) reduce lead revisions and prosthesis dysfunction compared to conventional transvalvular leads in patients with tricuspid valve replacement?
Absolute Event Rate: 2.5% vs 15.4%
p-value: p=0.286
Paravalvular positioning of pacemaker leads is a reasonable and durable alternative to conventional transvalvular positioning in patients undergoing tricuspid valve replacement.
Paravalvular leads may be reasonable in tricuspid valve replacement; observational data leaves open durability versus transvalvular approaches.
BACKGROUND: Bradycardic arrhythmias requiring pacemaker (PM) implantation are still common in patients in need of tricuspid valve replacement (TVR). Leaving an existing PM lead in an extravalvular position may represent a helpful alternative in special situations like the implantation of a mechanical TV. This study aimed to examine the short- to mid-term outcome of paravalvular leads concerning lead survival and prosthesis dysfunction in patients after TVR. METHODS: A retrospective case-control study of patients with TVR and ventricular pacing was conducted. Patients from the database of the Leipzig Heart Center were included. Data of the paravalvular lead group (PVG) and coronary sinus lead group (CSG) were compared to a control group with conventional transvalvular leads (TVG). RESULTS: Eighty patients with TVR and cardiac PM (TVG [n = 13], PVG [n = 40], and CSG [n = 27]) were included. The mean follow-up was 2.8 years. The rate of lead revisions (TVG 15.4%, PVG 2.5%, and CSG 7.5%) was lower in PVG but without significance (P = .286). The CSG demonstrated significantly higher pacing thresholds (1.4 V/0.8 ms) than TVG (0.5 V/0.4 ms), P = .004. However, the deterioration of threshold amplitudes during follow-up was similar in CSG (7.4%) and PVG (7.5%) compared with controls (7.7%). Function of TV prosthesis regarding development of stenosis or regurgitation showed a similarity between the groups (regurgitation PVG P = .692, CSG P = 1; stenosis PVG P = .586, CSG P = 0.69). CONCLUSION: Paravalvular positioning of PM leads seems to represent a reasonable alternative to the conventional transvalvular lead positioning concerning the lead and Tricuspid Valve prosthesis's function and durability in selected patients.
No takes yet. Share an insight, caveat, or question.
Michaelis et al. (2020) conducted a case-control in Tricuspid valve replacement and ventricular pacing (n=80). Paravalvular pacemaker leads vs. Conventional transvalvular leads was evaluated on Rate of lead revisions (p=0.286). Paravalvular positioning of pacemaker leads had a 2.5% rate of lead revisions compared to 15.4% for conventional transvalvular leads (P=0.286) after tricuspid valve replacement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: