Key result
Mathematical vector rotation generated personalized sensing vectors that increased the R:T ratio from 2.21 to 7.21, increasing S-ICD eligibility from 94.6% to 100%.
Why the study?
Approximately 5.7% of potential S-ICD recipients are ineligible due to vector morphology, and mathematical vector rotation is a novel technique to generate a personalized sensing vector with maximal R:T ratio.
Does mathematical vector rotation to generate personalized sensing vectors increase S-ICD eligibility while preserving arrhythmia detection performance compared to standard vectors?
Cohort (n=92)
Does mathematical vector rotation to generate personalized sensing vectors increase S-ICD eligibility while preserving arrhythmia detection performance compared to standard vectors?
Mathematical vector rotation can generate personalized sensing vectors that achieve universal S-ICD eligibility in previously ineligible patients without compromising arrhythmia detection performance.
Answers are grounded in this paper and cite their sources.
May enable universal S-ICD eligibility; leaves open prospective validation of detection performance.
AIMS: Approximately 5.7% of potential subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients are ineligible by virtue of their vector morphology, with higher rates of ineligibility observed in some at-risk groups. Mathematical vector rotation is a novel technique that can generate a personalized sensing vector, one with maximal R:T ratio, using electrocardiogram (ECG) signal recorded from the present S-ICD location. METHODS AND RESULTS: A cohort of S-ICD ineligible patients were identified through ECG screening of ICD patients with no ventricular pacing requirement and their personalized vectors were generated using ECG signal from a Holter monitor. Subcutaneous ICD eligibility in this cohort was then recalculated. In a separate cohort, episodes of arrhythmia were recorded in patients undergoing arrhythmia induction, and arrhythmia detection in standard S-ICD vectors was compared to rotated vectors using an S-ICD simulator. Ninety-two participants (mean age 64.9 ± 2.7 years) underwent screening and 5.4% were found to be S-ICD ineligible. Personalized vector generation increased the R:T ratio in these vectors from 2.21 to 7.21 (4.54-9.88, P < 0.001) increasing the cohort eligibility from 94.6% to 100%. Rotated S-ICD vectors also showed high ventricular fibrillation (VF) detection sensitivity (97.8%), low time to VF detection (6.1 s), and excellent tachycardia discrimination (sensitivity 96%, specificity 88%), with no significant differences between rotated and standard vectors. CONCLUSION: In S-ICD ineligible patients, mathematical vector rotation can generate a personalized vector that is associated with a significant increase in R:T ratio, resulting in universal device eligibility in our cohort. Ventricular fibrillation detection efficacy, time to VF detection, and tachycardia discrimination were not affected by vector rotation.
No takes yet. Share an insight, caveat, or question.
Wiles et al. (2021) conducted a cohort in Potential subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients (n=92). Mathematical vector rotation (personalized sensing vector) vs. Standard S-ICD vectors was evaluated on R:T ratio (95% CI 4.54-9.88, p=<0.001). Mathematical vector rotation generated personalized sensing vectors that increased the R:T ratio from 2.21 to 7.21, increasing S-ICD eligibility from 94.6% to 100%.