We propose a temperature-insensitive sensor using a compact X-cut thin-film lithium niobate (TFLN) Mach-Zehnder interferometer with quasi-symmetric arms (700 × 900 μm) and non-obstructive electrodes, suppressing thermal imbalance between waveguide arms. By optimizing the optical path difference and leveraging the low thermal expansion coefficient of silicon substrate, the sensor achieves intrinsic thermal stability without active tuning. Experimental results demonstrate 0.2 rad bias stability across 0 °C to 70 °C with < 2 dB RF response error for fields spanning 250 MHz – 3 GHz and 0 dBV/m – 45 dBV/m.