WO 3 nanostructures with monoclinic-hexagonal heterophase junctions (S-400) and the pure monoclinic phase of WO 3 were designed and prepared by the solvothermal method, combined with calcination at different temperatures. The WO 3 sensors exhibited p-type responses under low operating temperatures (≤100 °C) and n-type responses under high operating temperatures (≥200 °C) to the reducing gas NH 3 . Particularly, the S-400 sensor displayed outstanding sensitivity (133.2 to 100 ppm NH 3 ) and superior selectivity under a low operating temperature of 70 °C, which may be attributed to its intrinsic structure of heterophase junctions and surface state effects. Surprisingly, it was found that for the p-type conductive WO 3, the environmental humidity (ranging from 2 to 28%) positively affects its gas sensing performances to NH 3 . Thus, we proposed for the first time that the Brønsted acid sites formed on the WO 3 surface under 70 °C greatly facilitate adsorption of the alkaline gas NH 3, resulting in excellent sensitivity and selectivity.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: