Key result
Ultrasound was comparable to CT for detecting endoleaks after EVAR, demonstrating 85% sensitivity and 91% specificity, enabling a safe reduction of approximately 144 CT scans.
Why the study?
Does a simplified ultrasound-based surveillance protocol safely reduce the number of CT scans compared to conventional CT surveillance in patients after EVAR?
Cohort (n=56)
No
Does a simplified ultrasound-based surveillance protocol safely reduce the number of CT scans compared to conventional CT surveillance in patients after EVAR?
Ultrasound is comparable to CT for EVAR surveillance, allowing for a simplified protocol that safely reduces the number of required CT scans.
Answers are grounded in this paper and cite their sources.
Ultrasound may reduce CT scans in EVAR surveillance; leaves open prospective validation of safety and missed events.
BACKGROUND: Simplifying a postoperative surveillance protocol for endovascular aneurysm repair (EVAR) requires quality control comparing computerized tomography (CT) and ultrasound (US) results of abdominal aortic aneurysm (AAA) diameter measurements and endoleaks. PURPOSE: To test if US is comparable to CT, then assess a simplified follow-up with our conventional surveillance to assess patient safety. MATERIAL AND METHODS: During 2001-2006, data on 56 patients treated with Talent stent graft were prospectively registered. Median follow-up was 41.5 months (range, 2-94 months), with CT, US, and plain film abdomen X-rays (PFA) at 1, 6, and 12 months, then yearly. Bland-Altman plot was used to assess the agreement between CT and US measuring the AAA diameters and mixed model by the time effect to assess the difference in diameter over time. Sensitivity and specificity for detection of endoleaks by US, with CT as 'gold standard' were calculated. A simplified surveillance protocol with US/PFA at 6 and 8 weeks, CT/US/PFA at 1 year, and yearly US/PFA thereafter, was evaluated. CT was carried out when poor visibility, endoleak detected, AAA diameter increase (≥5 mm) on US or migration (≥10 mm) on PFA. This regime was compared with our conventional follow-up protocol. RESULTS: Diameter measurements on US appear comparable to CT with 91% specificity and 85% sensitivity for endoleaks detected by US. Using the simplified surveillance protocol no endoleaks, migrations, or endotension requiring treatment were overlooked. The simplified protocol generated 53 selective CT scans, avoiding approximately 144 CT scans. If further simplified by omitting the 1-year CT scan, one type II endoleak would be missed with a 1-year delay, eliminating a further 45 CT scans. CONCLUSION: US appears comparable to CT in the follow-up of Talent stent grafts in our institution. The proposed simplified surveillance protocol seems safe and can lead to a significant reduction in the number of CT scans.
No takes yet. Share an insight, caveat, or question.
Nyheim et al. (2013) conducted a cohort in Abdominal aortic aneurysm treated with endovascular aneurysm repair (EVAR) (n=56). Simplified surveillance protocol (ultrasound and plain film X-rays) vs. Conventional follow-up protocol (CT scans) was evaluated on Detection of endoleaks by ultrasound compared to CT as the gold standard. Ultrasound was comparable to CT for detecting endoleaks after EVAR, demonstrating 85% sensitivity and 91% specificity, enabling a safe reduction of approximately 144 CT scans.
Synapse has enriched 10 related papers. Consider them for comparative context: