Answers are grounded in this paper and cite their sources.
Three-port transformer attracts widely attention in the fields of electric vehicle and energy storage due to its potential for integration. Low-profile planar transformer is also able to achieve high power density as it helps switching frequency increases to MHz. Thus, three-port megahertz (MHz) transformer with PCB windings was adopted in the Regulated DC Transformer (RDCX) converter for high density on-board chargers (OBC). However, the transformer in RDCX suffers from decreased efficiency when the power distribution becomes imbalanced between different output ports. With the power distribution varies between two secondary windings in the three-port transformer, the winding loss increases during imbalanced power transfer, which is caused by the increase of the PCB winding magnetomotive force (MMF). Hence, a PCB arrangement method of minimizing MMF to reduce three-port high-frequency transformer winding loss is proposed and verified by experiment. The winding loss is reduced within the whole output voltage range, with a maximum reduction of 23%.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: