Answers are grounded in this paper and cite their sources.
A titration technique has been used to directly measure the proton uptake by ion‐exchange poly(2‐vinylpyridine) coatings as a function of solution pH. Contrary to the common assumption that each nitrogen in the pyridine ring is attached to an H+ when the polymer film is fully protonated, the use of the titration technique has shown that the portion of the pyridine sites actually protonated does not exceed 25% anywhere in the pH range where the coating is stable. The pKa value for the poly(2‐vinylpyridine) coating has also been estimated to be 4.5 from the titration curve.
No takes yet. Share an insight, caveat, or question.
Tantavichet et al. (2001) studied this question.