Sized glass fibres were administered to rats by intratracheal instillation to study the effect of fibre length and diameter on clearance and also on the solubility of fibres in the lung. The samples included 5, 10, 30 and 60 × 1.5 μm and 10 and 60 × 3 μm materials. After a year, about 90% of the 5 × 1.5 μm fibres had been cleared and about 80% of the 10 μm fibres. No significant clearance of the 30 and 60 μ fibres could be detected over the same period. All fibres were leached significantly during the investigation. The count median diameter (CMD) of the 5 × 1.5 μm fibres was reduced by about 12% over 18 months with little change in geometric standard diviation (σ g ). The CMD of the 10 × 1.5 μm fibres was reduced by 28% and there was an increase in σ g from 1.15 to 1.26. The 30 and 60 × 1.5 μm fibres dissolved much more rapidly and the CMDs of the residual populations after 18 months were less than half those of the original with a σ g of about 1.55. Many of the long fibres had fragmented and it is likely that some had dissolved completely at this time. These findings show that the behaviour of glass fibres in the lung is quite different from that of amphibole asbestos fibres which appear to be virtually insoluble in vivo. The health implications of these results are discussed.