The simple three-square-coil system reported here can produce a uniform magnetic field in a fairly large volume inside the coil system. The three square coils are of identical size. Two coils are placed in parallel at a distance of the side length of a square coil having the same ampere-turns, and the third is placed in the middle of the first two. The selected ampere-turn ratio of the side coil to that of the middle coil is 1:0.64. With this ampere- turn ratio, uniformity within 2% error is available in the region of 70% of the side length along the direction perpendicular to the square coil plane and 42% parallel to that direction. The magnetic field produced by this coil system has ripples unlike a Kakuno-Merritt three-coil system; it may be useful, however, for various experiments that do not require very smooth magnetic field distributions. The coil system has been successfully used in our laboratory for characterizing magnetic shields and for a magnetic tracking system.
No takes yet. Share an insight, caveat, or question.
I. Sasada (2003) studied this question.