Key result
An adaptive filtering technique increased the signal-to-interference ratio of raw surface EEnGs from 16.7 +/- 6.5 dB to 31.9 +/- 4.0 dB in conscious dogs.
Why the study?
Does an adaptive filtering technique based on signal averaging improve the signal-to-interference ratio of surface EEnGs by removing ECG interference in dogs?
Does an adaptive filtering technique based on signal averaging improve the signal-to-interference ratio of surface EEnGs by removing ECG interference in dogs?
An adaptive filtering technique based on signal averaging effectively removes ECG interference from surface electroenterograms, significantly improving signal quality.
Answers are grounded in this paper and cite their sources.
May facilitate preclinical surface EEnG studies; leaves open human translation and clinical utility.
An external electroenterogram (EEnG) is the recording of the small bowel myoelectrical signal using contact electrodes placed on the abdominal surface. It is a weak signal affected by possible movements and by the interferences of respiration and, principally, of the cardiac signal. In this paper an adaptive filtering technique was proposed to identify and subsequently cancel ECG interference on canine surface EEnGs by means of a signal averaging process time-locked with the R-wave. Twelve recording sessions were carried out on six conscious dogs in the fasting state. The adaptive filtering technique used increases the signal-to-interference ratio of the raw surface EEnG from 16.7 +/- 6.5 dB up to 31.9 +/- 4.0 dB. In addition to removing ECG interference, this technique has been proven to respect intestinal SB activity, i.e. the EEnG component associated with bowel contractions, despite the fact that they overlap in the frequency domain. In this way, more robust non-invasive intestinal motility indicators can be obtained with correlation coefficients of 0.68 +/- 0.09 with internal intestinal activity. The method proposed here may also be applied to other biological recordings affected by cardiac interference and could be a very helpful tool for future applications of non-invasive recordings of gastrointestinal signals.
No takes yet. Share an insight, caveat, or question.
Garcia‐Casado et al. (2006) studied ECG interference on surface EEnGs (n=6). Adaptive filtering technique based on signal averaging vs. Raw surface EEnG was evaluated on Signal-to-interference ratio. An adaptive filtering technique increased the signal-to-interference ratio of raw surface EEnGs from 16.7 +/- 6.5 dB to 31.9 +/- 4.0 dB in conscious dogs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: