Key result
The PSCOPE hybrid experimental-computational framework accurately modeled Fontan graft obstruction with normalized root-mean-square errors of 0.1% to 2.1% compared to established computational methods.
Why the study?
Advances in biomedical science leverage computational and experimental modeling platforms, motivating a hybrid framework that capitalizes on the strengths of both in a single model.
The PSCOPE hybrid experimental-computational framework provides a high-fidelity tool for physically testing medical devices like blood pumps with simulated physiologic feedback.
Answers are grounded in this paper and cite their sources.
Facilitates preclinical Fontan device testing; leaves open clinical translation pending human validation.
Significant advances in biomedical science often leverage powerful computational and experimental modeling platforms. We present a framework named physiology simulation coupled experiment ("PSCOPE") that can capitalize on the strengths of both types of platforms in a single hybrid model. PSCOPE uses an iterative method to couple an in vitro mock circuit to a lumped-parameter numerical simulation of physiology, obtaining closed-loop feedback between the two. We first compared the results of Fontan graft obstruction scenarios modeled using both PSCOPE and an established multiscale computational fluid dynamics method; the normalized root-mean-square error values of important physiologic parameters were between 0.1% and 2.1%, confirming the fidelity of the PSCOPE framework. Next, we demonstrate an example application of PSCOPE to model a scenario beyond the current capabilities of multiscale computational methods-the implantation of a Jarvik 2000 blood pump for cavopulmonary support in the single-ventricle circulation; we found that the commercial Jarvik 2000 controller can be modified to produce a suitable rotor speed for augmenting cardiac output by approximately 20% while maintaining blood pressures within safe ranges. The unified modeling framework enables a testing environment which simultaneously operates a medical device and performs computational simulations of the resulting physiology, providing a tool for physically testing medical devices with simulated physiologic feedback.
No takes yet. Share an insight, caveat, or question.
Kung et al. (2019) studied Fontan graft obstruction and single-ventricle circulation. PSCOPE hybrid experimental-computational modeling framework vs. Established multiscale computational fluid dynamics method was evaluated on Normalized root-mean-square error values of important physiologic parameters. The PSCOPE hybrid experimental-computational framework accurately modeled Fontan graft obstruction with normalized root-mean-square errors of 0.1% to 2.1% compared to established computational methods.