Key result
The Peritoneal Equilibration Test showed an inverse correlation between solute transfer and ultrafiltration volume, aiding in the evaluation of CAPD patients.
Why the study?
Does the Peritoneal Equilibration Test (PET) accurately assess solute transfer and ultrafiltration in CAPD patients?
Observational (n=104)
Does the Peritoneal Equilibration Test (PET) accurately assess solute transfer and ultrafiltration in CAPD patients?
The Peritoneal Equilibration Test is a reproducible and useful adjunct for understanding and prescribing peritoneal dialysis.
Answers are grounded in this paper and cite their sources.
Supports PET in CAPD evaluation; hypothesis-generating for transport-guided prescriptions, pending prospective validation.
A total of 143 Peritoneal Equilibration Tests (PETs) were performed in 104 CAPD patients over a period of 18 months. A normal range (95% confidence limits) was constructed from 100 tests (68 consecutive new patients, 32 routine tests on problem-free patients) using a 2-dimensional plot of solute transfer (D/Pcreat) and ultrafiltration volume. These two parameters correlated inversely (r = -0.59, P < 0.0001) allowing calculation of a regression line. In the short term (< 3 months) D/Pcreat was stable across a wide range of values (0.45-0.98) with good correlation between tests indicating reproducibility (r = 0.94, P < 0.001). Repeated tests beyond 3 months were variable, explaining changes in the clinical picture, and in the majority of cases shifts in D/Pcreat and ultrafiltration parallelled the regression line for the whole population. Six of seven (85%) of patients with mechanical problems and 14 of 15 (93%) with poor ultrafiltration had at least one abnormal test, and these two problems could be distinguished in 90% of cases by 2-dimensional plotting. In five with ultrafiltration failure, dialysate volumes were less than predicted by solute clearance, and these patients failed continuous cycling peritoneal dialysis (CCPD). In contrast, a good response to CCPD was predicted correctly in five patients with high solute clearance. In nine patients with plasma creatinine > 1250 mumol/l the PET was normal. The PET is a useful adjunct to understanding and prescribing peritoneal dialysis, particularly when repeated tests are compared to a well-defined normal population.
No takes yet. Share an insight, caveat, or question.
Davies et al. (1993) conducted an observational in Continuous Ambulatory Peritoneal Dialysis (CAPD) (n=104). Peritoneal Equilibration Test (PET) was evaluated on Correlation between solute transfer (D/Pcreat) and ultrafiltration volume (r = -0.59, p=< 0.0001). The Peritoneal Equilibration Test showed an inverse correlation between solute transfer and ultrafiltration volume, aiding in the evaluation of CAPD patients.
Synapse has enriched 10 related papers. Consider them for comparative context: