Answers are grounded in this paper and cite their sources.
The point-defect structure of monoclinic HfO2 (m-HfO2) was studied by means of equilibrium electrical conductance measurements as a function of temperature 1050≤T/K≤1200 and oxygen partial pressure −20≤log(pO2/bar)≤−2. The total conductivity σ displayed similar behavior at each temperature examined. In oxidizing conditions (pO2≥10−7bar), the total conductivity increased with increasing oxygen partial pressure and was assigned to hole conduction. Around 10−10 bar, a region of almost constant conductivity was found; this is ascribed to ionic conduction by means of doubly charged oxygen vacancies. In reducing conditions (pO2≤10−16bar), the total conductivity surprisingly decreased with decreasing oxygen partial pressure. Defect-chemical modeling indicates that this behavior is consistent with the conversion of mobile doubly charged oxygen vacancies into less mobile singly charged vacancies by electron trapping. Point-defect concentrations at the oxygen partial pressures relevant to resistive switching devices are predicted and discussed.
No takes yet. Share an insight, caveat, or question.
Mueller et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: