Key result
Incubation of human atrial myocytes with 10 microg/mL LPS significantly impaired the pacemaker current I(f) and increased its response to beta-adrenergic stimulation.
Why the study?
Does endotoxin (LPS) impair the pacemaker current I(f) in isolated human atrial myocytes?
Does endotoxin (LPS) impair the pacemaker current I(f) in isolated human atrial myocytes?
Endotoxin (LPS) directly impairs the cardiac pacemaker current I(f) in human atrial myocytes, potentially explaining the reduced heart rate variability observed in sepsis and heart failure.
LPS effects on atrial I(f) may link inflammation to arrhythmias; hypothesis-generating and requires in vivo confirmation before clinical consideration.
LPSs trigger the development of sepsis by gram-negative bacteria and cause a variety of biological effects on host cells, including alterations on ionic channels. Because heart rate variability is reduced in human sepsis and endotoxemia, we hypothesized that LPS affects the pacemaker current I(f) in human heart, which might--at least in part--explain this phenomenon. Isolated human myocytes from right atrial appendages were incubated for 6 to 10 h with LPS (1 and 10 microg/mL) and afterwards used to investigate the pacemaker current I(f). I(f) was measured with the whole-cell patch-clamp technique (at 37 degrees C). Incubation of atrial myocytes with 10 microg/mL LPS was found to significantly impair I(f) by suppressing the current at membrane potentials positive to -80 mV and slowing down current activation, but without effecting maximal current conductance. Furthermore, in incubated cells (10 microg/mL), the response of I(f) to [beta]-adrenergic stimulation (1 microM isoproterenol) was significantly larger compared with control cells (shift of half-maximal activation voltage to more positive potentials amounted to -10 and -14 mV in untreated and treated cells, respectively). Simulations using a spontaneously active sinoatrial cell model demonstrated that LPS-induced I(f) impairment reduced the responsiveness of the model cell to fluctuations of autonomic input. This study showed a direct impact of LPS on the cardiac pacemaker current I(f). The LPS-induced I(f) impairment may contribute to the clinically observed reduction in heart rate variability under septic conditions and in cardiac diseases such as heart failure, where endotoxin can be of pathophysiological relevance.
No takes yet. Share an insight, caveat, or question.
Zorn‐Pauly et al. (2007) studied Sepsis and endotoxemia. LPS (endotoxin) vs. Untreated control cells was evaluated on Pacemaker current I(f). Incubation of human atrial myocytes with 10 microg/mL LPS significantly impaired the pacemaker current I(f) and increased its response to beta-adrenergic stimulation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: