Answers are grounded in this paper and cite their sources.
An in situ accelerated mechanical stress test (ΔP-AMST) that applies relative humidity (RH) cycling combined with a pressure differential (ΔP) at a high temperature is proposed to accelerate mechanical degradation in all types of reinforced membranes used in fuel cells and obtain mechanical failure in a relatively short time. For validation, ePTFE reinforced membranes are mechanically degraded by RH cycling accelerated by means of a ΔP applied from cathode to anode using a custom designed polycarbonate spacer. Reinforced membrane failure detected by ΔP loss is reached within ∼10 to 10,000 RH cycles using this method, depending on the level of applied ΔP. The ΔP-AMST protocol is hence demonstrated as a fast, economical in situ alternative compared to existing methods for evaluating the mechanical fatigue durability of advanced fuel cell membranes.
No takes yet. Share an insight, caveat, or question.
Alavijeh et al. (2020) studied this question.