Key result
In patients with repaired tetralogy of Fallot, freedom from pulmonary valve reintervention was 94%, 77%, and 64% at 5, 10, and 15 years, with percutaneous valves showing lower longevity (P=0.007).
Why the study?
The longevity of bioprosthetic valves or valved conduits in the pulmonary position and the factors associated with their longevity in patients who underwent surgical repair of tetralogy of Fallot were not well defined.
What are the long-term durability and factors associated with reintervention of prosthetic pulmonary valves in patients with repaired tetralogy of Fallot?
Cohort (n=211)
No
What are the long-term durability and factors associated with reintervention of prosthetic pulmonary valves in patients with repaired tetralogy of Fallot?
In patients with repaired tetralogy of Fallot, younger age, smaller valve size, and male sex are associated with reduced durability of pulmonary bioprosthetic valves, with percutaneous valves showing lower longevity than surgical options.
Durability estimates for pulmonary BPVs in TOF now quantified; leaves open optimal valve selection pending prospective data.
OBJECTIVES: This study aimed to determine the longevity of bioprosthetic valves (BPVs) or valved conduits in the pulmonary position and the factors associated with prosthetic valve longevity in patients who underwent surgical repair of tetralogy of Fallot (TOF). METHODS: We performed a single-centre retrospective study in patients undergoing placement of a bioprosthesis or valved conduit in patients operated for TOF with a transannular patch. The primary end-point was freedom from pulmonary valve replacement (PVR) reintervention. The composite secondary end-point was freedom from PVR reintervention and structural valve degeneration. RESULTS: A total of 211 patients undergoing 255 operations were identified. The median age at first PVR was 15.4 years (IQR 12.3-20.7 years). The freedom from reintervention at 5, 10, and 15 years was 94%, 77%, and 64%, respectively. Multivariable analysis shows that factors that are independently associated with a more significant hazard of reintervention are younger age, smaller valve size, and male sex. Of the implanted prosthetic valves, 122 were bioprosthesis; 38 (18%) were homografts; 37 (17%) percutaneous valve, and 14 (7%) were other prosthetic valves or conduits. The freedom from reintervention was not different between homografts and all other heterografts (P = 0.938). Percutaneous valves showed an average longevity of 9.4 years, significantly lower than other prosthetic valves (P = 0.007). CONCLUSIONS: Younger patient age and a smaller valve size were associated with reduced BPV durability. There is a concern about an early PVR to preserve right ventricle function overall during adolescent age.
No takes yet. Share an insight, caveat, or question.
Brancaccio et al. (2025) conducted a cohort in Tetralogy of Fallot (n=211). Bioprosthetic valves or valved conduits in the pulmonary position vs. Different valve types (homografts, percutaneous, heterografts) was evaluated on Freedom from pulmonary valve replacement (PVR) reintervention. In patients with repaired tetralogy of Fallot, freedom from pulmonary valve reintervention was 94%, 77%, and 64% at 5, 10, and 15 years, with percutaneous valves showing lower longevity (P=0.007).