Key result
Biological pulmonary valves carry a ~49% re-replacement rate, linked to younger age and smaller diameter.
Why the study?
Factors impacting the longevity of biological valves in the pulmonary position in patients with tetralogy of Fallot or ToF-like anatomy were investigated due to uncertainty about valve durability.
What factors impact the longevity of biological valves in the pulmonary position in patients with tetralogy of Fallot?
Cohort (n=79)
What factors impact the longevity of biological valves in the pulmonary position in patients with tetralogy of Fallot?
In patients with tetralogy of Fallot, younger patient age is the crucial parameter predicting decreased longevity of biological valves in the pulmonary position.
Background In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated. Method Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2–56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11–29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: −1.8 to 4.0 SD; IQR: 2.1 SD). Results The median time of follow-up was 9.4 years (range: 1.1–18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007). Conclusion A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.
No takes yet. Share an insight, caveat, or question.
Müller et al. (2024) conducted a cohort in Tetralogy of Fallot (ToF) or ToF-like anatomy (n=79). Patient age, body surface area, internal valve diameter, and prosthesis z-score was evaluated on Surgical or interventional pulmonary valve re-replacement. Decreased longevity of biological valves in the pulmonary position (49% re-replacement rate) was significantly associated with younger age, lower valve diameter, and higher z-score.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: