Answers are grounded in this paper and cite their sources.
This study illustrates the capability of split-flow thin (SPLITT) fractionation on narrowing the size distribution of submicron pharmaceutical emulsions. We separated two different types of submicron pharmaceutical emulsions, both potential substitutes for red blood cells with centrifugal SPLITT fractionation. The size distribution of the emulsions was measured with sedimentation field-flow fractionation using a power program for optimal speed and resolution. The theoretically predicted size distribution of the fractionated emulsions closely matched the experimental size distribution. Reinjection of fractionated emulsions further narrowed the emulsion size distributions. Continuous separation of centrifugal SPLITT fractionation had a throughput of 15 g/h in this study. Guidelines for scaling up of this technique were provided. Centrifugal SPLITT fractionation could become a valuable technique in the pharmaceutical industry because of its capability for continuous separation and to control the cutoff size of submicron-sized emulsions.
No takes yet. Share an insight, caveat, or question.
Fuh et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: