Answers are grounded in this paper and cite their sources.
The voltammetric behavior of Ciprofloxacin (CIP) was investigated in different buffer solutions using cyclic voltammetry. It exhibited a single irreversible anodic peak with shift in peak potential with pH value which indicates proton dependent reaction. In a pH 4.0 phthalate buffer, a poorly defined oxidation peak current (i p ) is observed using carbon paste (CP) electrode for the determination of CIP using linear sweep adsorptive stripping voltammetric method (LS-AdASV). However, in the presence of low concentration of Cetyltrimethylammonium bromide (CTAB), i p enhancement occurs. Moreover, the usage of mesoporous carbon-modified carbon paste (MC/CP) electrode exhibits a significant enhancement in the i p . The enhancement of the i p of CIP at MC/CP electrode in the presence of CTAB [1.0 × 10 −4 M], was ascribed to two factors: (1) CTAB facilitates electron transfer of CIP; and (2) the high surface area of MC, which accumulates adsorptive CIP on the MC/CP electrode surface. All experimental parameters, were optimized for the determination of CIP. LS-AdASV method is observed to possess the following good qualities: high sensitivity (detection limit is 1.5 × 10 −9 M), wide linearity (5.0 × 10 −9 –2.0 × 10 −5 M), rapid response, low cost and simplicity. In conclusion, this method was employed to successfully detect CIP in pharmaceutical formulation and human serum.
No takes yet. Share an insight, caveat, or question.
Abdel-Galeil et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: