Key result
Electrokymographically recorded pulsatile movements of the aorta and pulmonary artery during voluntary straining provided a relative measure of diameter changes that qualitatively paralleled coincident changes in pulse pressure.
Why the study?
Does the electrokymographic method accurately measure diameter changes of the aorta and pulmonary artery during acute circulatory disturbances in healthy adults?
Observational (n=10)
No
Does the electrokymographic method accurately measure diameter changes of the aorta and pulmonary artery during acute circulatory disturbances in healthy adults?
The electrokymograph can measure relative diameter changes of the aorta and pulmonary artery during acute circulatory disturbances, though its accuracy is limited by the frequency response of the recording apparatus.
Answers are grounded in this paper and cite their sources.
Offers relative aortic/pulmonary diameter assessment during straining; leaves open quantitative validation against modern standards.
It has been demonstrated by Henny, Boone, Chamberlain, and their associates that border movements of the heart and great vessels may be recorded with the electrokymograph (1, 2, 4, 7). Confirmation of this work has been reported by others (3. 5, 6). Our studies were designed to investigate the accuracy with which movements of the aorta and pulmonary artery could be re- corded with this instrument, and the significance of these movements as measures of dynamic car- diovascular changes during certain acute disturb- ances of the circulation. For these experiments, acute intrathoracic pressure variation was chosen as the implement for the production of circula- tory disturbances. It is a procedure with which a new investigative method may be evaluated by comparison with observations of venous, arterial and pulmonary arterial blood pressure. cardiac output, roentgenokymographv, and roentgeno- graphic lung density in control studies or in the published reports of others.
No takes yet. Share an insight, caveat, or question.
Kay et al. (1949) conducted an observational in Healthy (n=10). Voluntary straining (modified Valsalva maneuver) vs. Resting control period was evaluated on Relative diameter change of the aorta and pulmonary artery compared to pulse pressure. Electrokymographically recorded pulsatile movements of the aorta and pulmonary artery during voluntary straining provided a relative measure of diameter changes that qualitatively paralleled coincident changes in pulse pressure.
Synapse has enriched 10 related papers. Consider them for comparative context: