This paper presents a new technique to design high-Q active resonators. The active resonators are then used in the design of low phase-noise oscillators. The proposed new technique uses an amplifier to generate a negative resistance, which compensates for the resonator losses and increases the Q factor. The active resonator using this technique shows a high loaded Q factor of 548.62 from measurement at the fixed 10-GHz resonant frequency. Considerations to design a voltage tunable active resonator is given and measurements show that the loaded Q factors exceed 500 with a 120-MHz tuning range. A low phase-noise free-running and voltage-controlled oscillator (VCO) were designed as an application of the proposed active resonators. The phase noise of the free-running oscillator using the active resonator is -114.36 dBc/Hz at 100-kHz offset, which is 14 dB lower than the phase noise of the passive resonator oscillator. In the case of a VCO using the active resonator, the phase-noise performance is below -110 dBc/Hz over the whole tuning range, which is lower 13 dB compared to the passive resonator VCO. The total dc power consumptions are approximately 500 mW.