Answers are grounded in this paper and cite their sources.
Centrifuge tests were conducted on driven in-flight fixed-head plumb and battered 3 × 3 pile groups at three-diameter (3D) and five-diameter (5D) spacings. The piles simulated 430-mm-diameter by 13-m-long pipe piles founded in medium loose (Dr = 33%) and medium dense (Dr = 55%) sands. The battered groups were in an A frame arrangement, i.e., each pile in a given row battered the same. Results of the tests showed that fixed-head plumb groups have a 30 to 55% higher lateral resistance than free-headed piles depending on soil density and pile spacing. For the battered 3D-spaced group, the lateral resistance was greater by 20 to 50% than the fixed-head plumb response in the medium dense sand; however, in the medium loose sand, the battered and plumb fixed-head group response was very similar. The latter is attributed to the limited axial tension capacity of the piles in the medium loose sand (Dr = 33%). Increasing the dead load on a battered group to 45% of its axial capacity resulted in a 30% increase in the group's lateral resistance. The lateral resistance of the 5D-spaced battered groups were in all cases greater than their 3D counterparts.
No takes yet. Share an insight, caveat, or question.
McVay et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: