This is the authors' abstract. We don't add key points for this paper.
Vibration control of cylindrical, electro-rheological fluid (ERF) dampers were studied. Single- as well as multi-electrode cylindrical ERF dampers were designed, built and tested under a forced vibration motion. Closed-loop, on-line control systems utilizing bang-hang and linear proportional controller were implemented to control the damping capacity of the ERF dampers. In addition, the designs were modified to reduce the required activation voltage. These modifications include increasing the electrode surface area as well as the number of electrodes. The damping ability of the dampers was further enhanced by using two identical dampers in series connection.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Gordaninejad et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: